Cracked tile, a missing liner, a stove on the wrong size flue
Send us the finding
Describe what the report says about the flue, or what the inspector told you. We call back with the likely fix.
What the camera shows
On the monitor, a sound clay flue looks like a square tube of pale tile with thin, even joints running up into the light. A failed one looks different. A dark line runs across a joint where two tiles have slipped apart. A crack splits a tile from top to bottom. A crust of black tar coats the lower third, thick enough that the light barely bounces back. Sometimes there is no tile at all, just bare brick, because the chimney was built before liners were common or the tile was lost in a fire.
Each of those is a reason a flue fails Level 2, and each has its own fix.
- Cracked or offset tile: smoke and heat can reach the brick
- No liner: nothing between the fire and the masonry
- Heavy tar: fuel for a chimney fire
- Flue far larger than the stove: smoke cools and coats the tile
Relining: the usual answer for wood burners
For a flue with cracked tile, a missing liner or a size that does not suit the stove, the usual fix is a stainless steel liner run from the appliance to the top. It is sized to the stove or insert, sealed along its length, and finished with a top plate and cap. The old tile stays where it is; the smoke never touches it again.
Where the tile is sound but coated, a sweep may be all it needs, followed by a change in burning habits. Where the chimney's masonry is breaking up above the roof, the liner waits until that is repaired. Liners, crowns, dampers and chase covers have no fixed price on our list, so each gets a written figure once we have measured.
The other common findings
Not every failure is inside the flue. A missing cap lets rain and nests in. Water getting past the flashing stains the ceiling beside the chimney. A wide chimney on a sloped roof catches water behind it until a small diverter is built there. These are the items we have prices for, and they sit in the table below.
Some owners decide a failed flue is the moment to stop burning wood. A gas insert set into the existing fireplace with its own vent up the chimney settles the flue question in one job.
Fix prices we publish
These are installed prices. Where a range is shown, size and materials decide where in it your job lands.
- Camera run to confirm the flue (Level 2)
- $405
- Finding and stopping a roofline leak
- $580 to $3,450
- Water diverter on the uphill side
- $465 to $1,045
- Diverter plus new metal at the roof joint
- $695 to $1,700
- Switching the fireplace to a gas unit
- $2,900 to $5,800
- Cap with rain hood and spark mesh
- Quoted after we measure
There is no set price for a liner, crown, damper or chase cover, or for flashing done alone. We measure each and write the figure down.
Questions after a failed inspection
Do I need a liner, or just a sweep?
If the tile is sound and the problem is tar, a sweep may do. If tile is cracked, shifted or missing, or the flue is far too big for the stove, a liner is the usual fix.
Can I keep burning until the repair is done?
It depends on the finding. The report marks whether the flue is safe to use meanwhile. Cracked tile or no liner usually means no fires until it is fixed.
Will the chimney pass after relining?
A properly sized and installed liner deals with the flue findings. We can run the camera again after the work if a buyer or insurer wants to see it.
Why do liners not have a fixed price?
Height, diameter, offsets and the connection at the bottom differ on every chimney. We measure first and write the figure down.
Should I switch to gas instead?
If you rarely burn wood, it can make sense. A gas insert vents through its own liner and avoids the tar question entirely.
Turn the failed report into a repair list
Describe the findings through the contact form and we will come out to Signal Hill, Long Beach, Carson or Cerritos to measure and write up the fix.
Call (562) 449-0518